SC 803-366-5131 | TN 615-254-0841

Air-Flow-Calibrators

Digital Calibrators (FSD-828 and FSD-8528)

FSD-812 Digital Calibrators (FSD-828 and FSD-8528)

FSD-812

  • FSD-812
  • Not Shown (FSD-828 and FSD-8528)
  • Rugged construction
  • Direct reading -/+ in CFM or LPM
  • Better than +/- 5% accuracy of full scale
  • Three flow ranges (see chart on bottom)
  • Certified and traceable to NIST

RAD?CO Air Flow Calibrators are the most durable and repeatable calibration devices available. RAD?CO calibrators are constructed of a precision machined aluminum venturi tube and an appropriately ranged intelligent digital meter mounted in a rugged steel case. Simple, cost effective and consistently accurate year after year.

RAD?CO Air Flow Calibrators are available calibrated in cubic feet per minute or in liters per minute. Each calibrator is individually calibrated to an air flow instrumentation system whose calibration is certified and traceable to the National Institute of Standards and Technology (NIST). The RAD?CO Air Flow Calibrators are guaranteed to an accuracy of better than +5%, referenced to 29.92 inches of mercury and 70°F. A Certificate of Calibration is supplied with each calibrator.

RAD?CO maintains an Air Flow Calibrator recertification and repair service for all RAD?CO units. Similar units manufactured by competitors can also be serviced at our facility. Special calibrations are available upon request. An assortment of adaptors is available which mate the calibrators to all RAD?CO Sample Holders.

Specifications

Accuracy: Better than +/- 5% at 29.92”Hg and 70°F

Weight: Less than 5 pounds (2.3 Kg)

Calibration Frequency: For calibration laboratory userecertification is suggested once every two years; for field or dusty environment use, calibration recommended once a year.

120-220VAC 50/60hz, <1 amp

 

AIR FLOW

RANGES

AVAILABLE

Model No.
Cubic Feet Per Minute
Liters Per Minute

FSD-812

0.5 to 3.5

10 to 100

FSD-828

1 to 8

25 to 225

FSD-8528

1 to 28

* USAF KIT RANGES 2 to 20

25 to 800

 

AIR FLOW CALIBRATOR ADAPTORS

Model No.

Description

FS2500-43

Adapts FSD-8528 to Sample Head 2500-25A

FS2500-54

Adapts FSD-8528 to Staplex 4” Sample Head

FS2500-60

Adapts FSD-8528 to Sample Head 2500-23

FS2500-61

Adapts FSD-8528 to Sample Head 2500-33

FS2500-83

Adapts FSD-8528 to Sample Heads 2500-05, -19, 21-, -27, 41, 45

FS2500-86

Adapts FSD-8528 to Sample Heads 2500-34, -35, -39, -40, -44, -46

FS2500-55

Adapts FSD-8528 to Sample Heads 2500-34, -35, -39, -40, -44, -46

FS2500-56

Adapts FSD-828 to Sample Heads 2500-05, -19, -21, -27, -41, -45

FS2500-57

Adapts FSD-828 to Sample Head 2500-33

FS2500-58

Adapts FSD-828 to Sample Head 2500-23

FS2500-79

Adapts FSD-812 to Sample Heads 2500-35, -46

FS2500-80

Adapts FSD-812 to Sample Heads 2500-05, -21

FS2500-81

Adapts FSD-812 to Sample Head 2500-42

FS2500-82

Adapts FSD-812 to Sample Head 2500-04

FS2500-53

Adapts FSD-812 to Sample Heads 2500-06, -07

Contact Tennessee Branch

Contact South Carolina Branch

Air Flow Calibrator (FSC-828 and FSC-8528)

FSC-812 Air Flow Calibrator (FSC-828 and FSC-8528)

FSC-812

  • FSC-812
  • Not Shown (FSC-828 and FSC-8528)
  • Direct reading in CFM or LPM
  • Reflective arc for parallax correction
  • Better than +5% accuracy full scale
  • Three flow ranges (see chart on bottom)
  • Calibration certified and traceable to NIST
Twenty-five Years of Proven Reliability

RAD?CO Air Flow Calibrators are the most durable and repeatable calibration devices available. RAD?CO calibrators are constructed of a precision machined aluminum venturi tube and an appropriately ranged magnehelic gauge mounted in a rugged steel case. Simple, cost effective and consistently accurate year after year.

RAD?CO Air Flow Calibrators are available calibrated in cubic feet per minute or in liters per minute. Dual calibrations are available on special request. Each calibrator is individually calibrated to an air flow instrumentation system whose calibration is certified and traceable to the National Institute of Standards and Technology (NIST). The RAD?CO Air Flow Calibrators are guaranteed to an accuracy of better than +5% FS, referenced to 29.92 inches of mercury and 70°F. A Certificate of Calibration is supplied with each air flow calibrator.

RAD?CO maintains an Air Flow Calibrator recertification and repair service for all RAD?CO units. Similar units manufactured by competitors can also be serviced at our facility. Special calibrations are available upon request. An assortment of adaptors are available which mate the calibrators to various RAD?CO Sample Holders.

Specifications

  • Accuracy: Better than +5% FS at 29.92”Hg and 70°F
  • Weight: Less than 5 pounds (2.3 Kg)
  • Calibration Frequency: For calibration laboratory use recertification is suggested once every two years; for field or dusty environment use, calibration should be once a year.

 

AIR FLOW

RANGES

AVAILABLE

Model No.

Cubic Feet Per Minute

Liters Per Minute

FSC-812

0.5 to 3

10 to 90

FSC-828

1 to 8

25 to 225

FSC-8528

4 to 28

100 to 800

 

AIR FLOW CALIBRATOR ADAPTORS

Model No.

Description

FS2500-43

Adapts FSC-8528 to Sample Head 2500-25A

FS2500-54

Adapts FSC-8528 to Staplex 4” Sample Head

FS2500-60

Adapts FSC-8528 to Sample Head 2500-23

FS2500-61

Adapts FSC-8528 to Sample Head 2500-33

FS2500-83

Adapts FSC-8528 to Sample Heads 2500-05, -19, 21-, -27, 41, 45

FS2500-86

Adapts FSC-8528 to Sample Heads 2500-34, -35, -39, -40, -44, -46

FS2500-55

Adapts FSC-8528 to Sample Heads 2500-34, -35, -39, -40, -44, -46

FS2500-56

Adapts FSC-828 to Sample Heads 2500-05, -19, -21, -27, -41, -45

FS2500-57

Adapts FSC-828 to Sample Head 2500-33

FS2500-58

Adapts FSC-828 to Sample Head 2500-23

FS2500-79

Adapts FSC-812 to Sample Heads 2500-35, -46

FS2500-80

Adapts FSC-812 to Sample Heads 2500-05, -21

FS2500-81

Adapts FSC-812 to Sample Head 2500-42

FS2500-82

Adapts FSC-812 to Sample Head 2500-04

FS2500-53

Adapts FSC-812 to Sample Heads 2500-06, -07

Contact Tennessee Branch

Contact South Carolina Branch